D. The AV Contractor shall have nationally certified installation technicians.
E. The AV Contractor shall provide references pertaining to similar sized projects on
request.
F. The AV Contractor shall have a certified BSS Audio Soundweb London DSP
programmer on staff with three years experience. The DSP program shall be
submitted to the Design Consultant two weeks before final system commissioning.
G. The AV Contractor shall comply with the NEC in relation to installation of
components and system wiring.
H. The AV Contractor shall provide training on the systems. Training shall be hands on
by demonstration of system functions.
I. All equipment and installation, including Audio/Video wiring shall be guaranteed for
12 months from final acceptance of completion.
J. Substitutions
a. Request for substitution shall be submitted ten working days before the bid is due.
The request shall include the make and model, and a copy of the architects and
engineering specification of the equipment along with a copy of the system diagram
drawings showing the implementation of the alternate equipment. Failure to
provide a request for substitution is grounds for rejecting the bid.
b. Substitutions after submittals have been reviewed shall not be allowed unless the
product has been discontinued. Alternatives for discontinued product must be
reviewed by the Design Consultant as soon as a known replacement product is
available.
c. Alternate equipment must be equal or better in all performance characteristics.
d. Any additional cost due to alternate equipment shall reviewed and by Owner before
approval.
e. Any cost savings from alternate equipment shall be passed as a credit to the Owner.
1.4 Submittals and Documentation
A. Shop Drawings (provide the following for approval):
a. Drawings rendered by the AV Contractor in Visio or AutoCAD. The functional
block diagram shall show all equipment and connections including control system
wiring.
b. Rack elevations shall be submitted
c. Speaker rigging and location shall be submitted.
B. As Built drawings: Provide one three ring binder or expanding partitioned file folder
with the following categories clearly labeled. A CD with the following information as
PDF files neatly organized into a logical folder structure shall also be required.
a. Functional Block diagram reflecting final installed system (As Built)
b. Service and Operations Manuals provided by the manufacturer of equipment.
c. Statement of Warranty for equipment if not provided in the above manual
d. DSP program file saved to a CD.
e. Crestron program file saved to a CD
f. Operating instructions specifically written for the system called out in this
specification.
g. “Quick Reference” instruction sheet laminated to provide simple instruction for
room subsystems shall be provided at the request of the owner or Architect
Engineer